Basic Controls |
|
RBC-AMT31E |
Wired Remote Control
with integrated sensor, alarm display and configuration
options, can be group up to 8 indoor units. |
|
RBC-AS21E2
|
Simplified Wired Remote
Control with integrated sensor. Can group up to 8
indoor units. |
|
RBC-EXW21E |
Weekly Timer that
connects to standard controller or central.
Includes omit/copy function. |
|
TCB-EXS21TLE |
Weekly/Schedule
Timer that connects to standard controller or central.
Includes omit/copy function per group for up to 8 groups
of 8 units. |
|
RBC-AX22CE2
|
Infra Red Remote Kit
(Ceiling or 1 Way), can group up to 8, Integrated sensor |
|
TCB-AX21E2
|
Infra Red Remote Kit
(Ducted), surface mounted receiver |
|
VN
Control Options |
This section is subdivided into four sections for
different applications of the VN units. The VN is
supplied with a 240V control option as standard this is
a starting point but often requires development for
specific applications. |
|
TCB-TC21LE2 |
Remote Sensor that
provides a single temperature value to the entire group |
|
RBC-AX31U(W)-E |
Infra Red Remote Kit
(4 Series 4 Way Cass) , Can group up to 8, includes
grille corner pocket |
|
TCB-AX21U(W)-E2 |
Infra Red Remote Kit
(4 Way Cass) , Can group up to 8, includes grille corner
pocket |
|
|
|
Timed On/Off Control |
|
RBC-SMTI |
The interface lead consists
of a 1 meter two core cable and connector, designed for
direct connection to the following accessories:
RBC-AMT21E, RBC-AMT31E, TCB-SC64TLE, TCB-CC163TLE2
|
|
RBC-IT4-PE |
The RBC-IT4PE time switch
interface is intended for use with the TOSHIBA DI/SDI/SMMS/SHRM
range of indoor units and is designed to allow these systems
to be externally switched on and off by means of any
volt-free external terminals rated at 230 volts a/c. |
|
RBC-IT3-PE |
The RBC-IT3PE time switch
interface is intended for use with the TOSHIBA Daiseikai range of indoor units and is
designed to allow these systems to be externally switched on
and off by means of any volt-free external terminals rated
at 230 volts a/c. |
|
RBC-SMCN61 |
The interface lead consists
of a 1 meter three core cable, which can connect to any
R410A DI/SDI or SMMS/SHRM indoor unit. The accessory allows
the indoor unit to be enabled / disabled by a volt free
contact closure. It also allows the remote to be locked to
prevent the unit being switched on. |
|
|
|
Output Circuits
(Indoor) |
|
RBC-SMFI |
The fan interface module will
allow an external ventilation fan to be controlled from an
indoor unit. The device consists of a single pole relay
housed in a small electrical enclosure, which connects to a
Digital Inverter or VRF indoor unit via the supplied
connection lead. |
|
RBC-SMIM2 |
The device is designed to
give the operational status of DI/SDI and SMMS/SHRM systems.
An indication of whether a
system is heating, cooling or the fan is operating is given
via a series of LED’s and the activation of a relay output.
The volt free relay output terminals allow for remote
interfacing with a control panel or BMS system.
|
|
RBC-SMIM3 |
The device is designed to
give the operation and fault status for DI/SDI/SMMS/SHRM
systems. An indication of whether a system operating or has
a stopping fault is given via a pair of LED’s located on the
device and the activation of a relay output. The volt free
relay output terminals allow for remote interfacing with a
control panel or BMS system. |
|
RBC-FDP2-F-PE |
Fault Display Module
switches up to 24VAC for external indication of any
fault code within group. Has optional preset
parameters. Can be connected to another FDP2 to
provide run/standby with daily changeover. |
|
RBC-FDP2-BMS |
The FDP2- BMS is an interface
that has the ability to accept inputs from an analogue BMS
system. The inputs to the controller can be either voltage
or resistance this can be configured on the FDP2-BMS. The
device also has a relay output that closes in the event of a
fault within the system. |
|
TCB-IFCB-4E2 |
The device is designed to
give remote on/off control, operation and remote fault
indication for DI/SDI/SMMS/SHRM systems. The device may be
connected to single indoor units or one device may be
connected to a group of indoor units. |
|
|
|
Output Circuits
(Outdoor) |
|
TCB-PCM02E |
The accessory is designed to
fit into the SMMS or SHRM outdoor unit; it is a PCB that can
be used to perform several different functions. The PCB
accepts an input that would be volt free from an external
source to enable the required function. |
|
TCB-PCIN2E |
The device is designed for
use on the SMMS/SHRM systems and consists of a PCB, which
provides a relay contact closure when the system is
operating or in the event of a fault. |
|
TCB-PCDM2E |
This device is intended for
use on the SMMS/SHRM systems and is designed to limit the
maximum operating capacity of a system, which will
consequently restrict the power consumption. |
|
TCB-PCOS1E |
The device is intended for
installation on the DI outdoor unit range and has been
designed to limit the outdoor unit noise production in the
cooling mode by 5dB, limit the maximum power consumption and
give a compressor operation signal. The noise and power
functions are individually initiated by a relay contact
closure, which may be a time clock, switch or any other
suitably rated device. The compressor operation signal is
given via a volt free contact closure. |
|
|
|
Central Control |
|
TCB-SC642TLE2 |
Central Remote Control
connecting to U1-U2 or U3-U4 network. Provides
operating instructions to up to 64 VRF indoor units or
64 groups of split system indoors. Includes Alarm
display. Can be one of 10 controllers in a
network. Local controllers can be used with last touch
priority unless restricted by central. Requires
240 VAC power supply. |
|
RBC-CC163TLE2 |
The on/off
controller is a product that is capable of operating 16
indoor units from a single location. The device consists
of 16 individual on/off buttons, which allows any
connected units to be enabled or disabled via a single
button operation. It is also possible to enable or
disable all of the connected units via single button
operation. |
|
TCB-PCNT20TLE |
The device is intended for
use on the DI/SDI/SMMS/SHRM ranges of equipment and is
designed to convert TCC Link to AI Network protocol. This
enables earlier types of control equipment to be interfaced
with the current range. |
|
TCB-PCNT30TLE |
DI/SDI Indoor to TCC
Link Connects to CN50. Not required by VRF
indoors or KRT systems. 600mm cassettes require
additional mounting box to use TCB-PX30MUE, |
|
|
|
BMS
Controls |
|
RBC-WP1-PE |
The RBC-WP1-PE is a
front-end software package that controls all aspects of
the air conditioning systems installed on a site. The
software is installed on a PC, which then connects to a
TCB-IFLN640TLE2 LonWorks gateway for connection to the
indoor units. |
|
RBC-EM1-PE |
The RBC-EM1-PE consists of a power meter and
current transformers. All these components are required to
be mounted in a suitable enclosure. The power meters then
connect directly to the windows package. The RBC-EM1-PE kit
consists of a Lon works power meter and a set of three
current transformers, one for each phase. |
|
RBC-DI1-PE
|
The RBC-DI1 is a module that connects to the
LonWorks network that links back to the Interactive
Intelligence software running on a PC in the building. The
module has 8 digital inputs and eight relay outputs. These
inputs can be used to control external plant or except
inputs from other plant.
|
|
TCB-IFLN640TLE |
The LonWorks gateway is a device that allows
the Toshiba indoor units to be connected to a LonWorks based
BMS. The gateway uses all standard network variables
contained in individual function blocks for each indoor
unit. The gateway can communicate with up to 64 indoor units
on a U1/U2 Network. |
|
Touch Screen Control |
The Touch Screen Controller is an advanced
central controller, which is available in various different
formats. It is available in four formats, to control
sixty-four or five hundred and twelve indoor units, each of
which are available with or without the billing function.
The Touch Screen allows full unit control of all connected
indoor units and is capable of giving full fault and
operating information. The controller has the ability to
schedule on/off times for each individual indoor unit. |
|
BACnet Interface |
The BACnet solution allows the Toshiba
indoor units to be connected to a BACnet over IP based BMS.
The gateway uses all standard BACnet objects for the control
and monitoring of each indoor unit. |
|
LTX-21 |
Trend BMS Connection |
|
LTX-51
|
Modbus Serial Port
Connection |
|
|
|
Other Accessories |
|
RBC-CBK15FE |
FS Box Control Extension
10M |
|
RBC-SHA1LE |
RAS Ducted Wired Remote |
|
RBC-TWP30E |
Twin Pipe Kit for
1102/4 |
|
RBC-TWP50E |
Twin Pipe Kit for
1402/4 |
|
|