TOSHIBA > TCC LINK CONTROLS > RBC-WP1-PE

 

 

 

- Front End Control Package
- Connects via LonWorks
- Fully Customisable

RBC-WP1-PE
WINDOWS CONTROL PACKAGE

RBC-WP1-PE

The RBC-WP1-PE is a front-end software package that controls all aspects of the air conditioning systems installed on a site. The software is installed on a PC, which then connects to a TCB-IFLN640TLE2 LonWorks gateway for connection to the indoor units.

The software allows all of the units operating parameters to be adjusted from the one PC.

It allows faults to be reported and re-transmitted via email, fax or text message. The software can be accessed remotely either by telephone or via the Internet. The software can log data and provide graphical representation of data. It has a schedule built-in for time control and it can also be used to reset set points or modes of operation.

When the software is installed, it will automatically install the gateways and power meters and it will then generate basic graphics.

 

Application

The software is used when a computer solution is required in order to provide a flexible solution to allow the air conditioning to be fully controlled from one central point. It offers much functionality, which is suited to small and large systems.

Connections

The Windows Package (RBC-WP1-PE) connects to a LonWorks gateway via the AB network.

The AB network is connected via a two part screw terminal connector the recommended cable is 2-Core Screened 1.5mm2. The connector is mounted on a full height PCI card that is fitted to the PC Limits

The windows package can control up to 1024 indoor units connected through the LonWorks gateways (one gateway required per 64 indoor units).
 

Features of the Software

Customization

The software being very flexible, it allows for a fully adaptable graphical representation of the building to be included.

Frost Protection

The software has the ability to sample the air temperature from an individual or a selection of indoor units. Then, based on this data, operate the air conditioning to give frost and fabric protection to the building

Energy monitoring

The energy monitoring software can be included to calculate the running costs of the individual indoor units. This data can then be provided in structured bills for the building tenants. This data is calculated from the demand given from the indoor units and the power consumed by the system. The RBC-EM1-PE power meter is required for this function. This option is covered in a separate data sheet.

Control of other devices

We have a simple digital Input / Output module that we use to control other plant systems. For example, we could enable boilers or other air-handling units. The module can accept inputs also; examples would be an input from a fire alarm where the air conditioners are shutdown or an input to switch on the air conditioners from an external source. The RBCDI1 module is required for this function. This option is covered in a separate data sheet.
 

PC Minimum Specification

Toshiba does not provide the PC. The minimum requirements for this PC to run the Toshiba Windows Package are:

P4 2GHz or Equivalent
20G HDD
512M RAM
Separate Video Card
Full size case to Accept a Standard size PCI card
 

Solution Components

RBC-WP1-PE

Windows package will be required to configure and receive alarms from the remote site.

TCB-IFLN640TLE2

The LonWorks gateway will be required for every 64 indoor units.

TCB-PCNT30TLE2

Network adapters will be required for each Toshiba Digital Inverter and Super Digital Inverter indoor unit.

RBC-EM1-PE

If energy monitoring is required, an RBC-EM1-PE kit is required for each refrigerant system.

RBC-DI1-PE

If external control is required for other equipment, the RBC-DI1-PE will provide 8 digital inputs and 8 relay outputs.
 


Downloads



RBC-WP1-PE Wiring Diagram

 


home - about us - toshiba - carrier - accessories - contact