TOSHIBA > RESIDENTIAL > R410A TWIN/TRIPLE/QUAD-SPLIT

 

 

 

 

 

R410A TWIN/TRIPLE-SPLIT
DIGITAL INVERTER +
SUPER DIGITAL INVERTER

Twin/Triple-Split SDI/DI
Light Commercial.


Features

The twin/triple/quad-split system allows the connection of two/three/four indoor units of the same type and the same capacity to one outdoor unit in order to ensure more even air distribution in a larger zone. The master unit measures the temperature for both indoor units. The indoor units are installed in the same room, always operate simultaneously, and have a single control.

Key features

It is possible to twin, triple or quad this system with four-way cassette, ducted, high-wall and ceiling indoor units.

Precise capacity control at all conditions.

Ideal for larger shops, open-plan offices and other similar applications.

User-friendly controls.

Compact outdoor unit for easy installation.

Performance tuning for optimised comfort.

Twinning or tripling requires a connection kit consisting of an electromagnetic noise suppressor and pipe joint
 

PDF Manuals available for this product

 

Product Specification

DIGITAL INVERTER TWIN/TRIPLE

Outdoor Unit (with DI)   RAV-SM1103AT RAV-SM1403AT RAV-SM1603AT RAV-SM1603AT
Twin/Triple Cassettes   2 x RAV-SM564UT 2 x RAV-SM804UT 2 x RAV-SM804UT 3 x RAV-SM564UT
Twin/Triple Compact Cassettes   2 x RAV-SM562MUT n/a n/a 3 x RAV-SM562MUT
Twin/Triple Ducted   2 x RAV-SM562BT 2 x RAV-SM802BT 2 x RAV-SM802BT 3 x RAV-SM562BT
Twin/Triple Slim Ducted   2 x RAV-SM564SDT n/a n/a 3 x RAV-SM564SDT
Twin/Triple Ceiling   2 x RAV-SM562CT 2 x RAV-SM802CT 2 x RAV-SM802CT 3 x RAV-SM562CT
Twin/Triple Wall   2 x RAV-SM562KRT 2 x RAV-SM802KRT 2 x RAV-SM802KRT 3 x RAV-SM562KRT
* Please note that a twin/triple kit is required

DIGITAL INVERTER LARGE TWIN

 
Outdoor Unit (with DI)   RAV-SM2244AT8 RAV-SM2804AT8    
Twin Cassette   2 x RAV-SM1104UT 2 x RAV-SM1404UT    
Twin Ducted   2 x RAV-SM1102BT 2 x RAV-SM1402BT    
Twin Ceiling   2 x RAV-SM1102CT 2 x RAV-SM1402CT    
* Please note that a twin kit RBC-TWP101E is required
 

DIGITAL INVERTER LARGE TRIPLE

 
Outdoor Unit (with DI)   RAV-SM2244AT8 RAV-SM2804AT8    
Triple Cassette   3 x RAV-SM804UT 3 x RAV-SM804UT    
Triple Ducted   3 x RAV-SM802BT 3 x RAV-SM802BT    
Triple Ceiling   3 x RAV-SM802CT 3 x RAV-SM802CT    
Triple Wall   3 x RAV-SM802KRT 3 x RAV-SM802KRT    
 

DIGITAL INVERTER LARGE QUAD

 
Outdoor Unit (with DI)   RAV-SM2244AT8 RAV-SM2804AT8    
Quad Cassette   4 x RAV-SM564UT 4 x RAV-SM804UT    
Quad Ducted   4 x RAV-SM562BT 4 x RAV-SM802BT    
Quad Ceiling   4 x RAV-SM562CT 4 x RAV-SM802CT    
Quad Wall   4 x RAV-SM562KRT 4 x RAV-SM802KRT    
Quad Compact Cassette   4 x RAV-SM562MUT n/a    
Quad Slim Duct   4 x RAV-SM562SDT n/a    
 

Click here to see outdoor unit for refrigerant circuit details

           
   

SUPER DIGITAL INVERTER TWIN

   
           
Outdoor Unit (with SDI)   RAV-SP804AT RAV-SP1104AT RAV-SP1404AT  
Twin Cassettes  

n/a

2 x RAV-SM564UT 2 x RAV-SM804UT  
Twin Compact Cassettes   2 x RAV-SM404MUT

n/a

n/a  
Twin Compact Cassettes   n/a 2 x RAV-SM562MUT n/a  
Twin Ducted   n/a 2 x RAV-SM562BT 2 x RAV-SM802BT  
Twin Slim Ducted   n/a 2 x RAV-SM564SDT n/a  
Twin Slim Ducted   2 x RAV-SM404SDT n/a n/a  
Twin Ceiling   n/a 2 x RAV-SM562CT 2 x RAV-SM802CT  
Twin Wall   n/a 2 x RAV-SM562KRT 2 x RAV-SM802KRT  
 
           

Click here to see outdoor unit for refrigerant circuit details

           
   

INSTALLATION DETAILS

   
Outdoor Size   804 1103/4 1403/4 1603
Supply Taken to   Outdoor Outdoor Outdoor Outdoor
Interconnecting to Master   3 + E 3 + E 3 + E 3 + E
Interconnecting Master - Slave   2 + E (T1, T2) 2 + E (T1, T2) 2 + E (T1, T2) 2 + E (T1, T2)
Remote to Master   A+B A+B A+B A+B
Remote Master - Slave   A+B A+B A+B A+B
           
Piping Details          
Outdoor to T gas / liquid   5/8 - 3/8 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8
T to Indoors  gas / liquid 1/2 - 1/4 1/2 - 1/4 5/8 - 3/8
Connection Kit RBC-TWP30E RBC-TWP50E RBC-TWP50E RBC-TRP100E
   

INSTALLATION DETAILS - LARGE CONDENSING UNITS

   
Outdoor Size   2244 2804    
Supply Taken to   Outdoor Outdoor    
Interconnecting to Master   3 + E 3 + E    
Interconnecting Master - Slave   2 + E (T1, T2) 2 + E (T1, T2)    
Remote to Master   A+B A+B    
Remote Master - Slave   A+B A+B    
           
Piping Details          
Outdoor to T gas / liquid   1 1/8 - 1/2 1 1/8 - 1/2    
1st T to Indoors (Twin/Triple) 3/8 - 5/8 3/8 - 5/8
2nd T to Indoors (Quad) 3/8 - 1/2 3/8 - 5/8
Connection Kit - Twin RBC-TWP101E RBC-TWP101E
Connection Kit - Triple RBC-TRP100E RBC-TRP100E
Connection Kit - Quad RBC-DTWP101E RBC-DTWP101E


 

 

home - about us - toshiba - carrier - accessories - contact