TOSHIBA > LIGHT COMMERCIAL > 4-WAY CASSETTE

 

- Easy controls access via corner pockets
- High ceiling temperature sensor control
- Infra-red control option Built-in lift pump
- Individual Louvre Control

 

 

 

R410A HEAT PUMPS
DIGITAL/SUPER DIGITAL
INVERTER
CLASSIC CASSETTE

4-way cassette SDI/DI
Light Commercial


Features

This new four way cassette is unobtrusive and flexible and can easily blend in with any room interior.

Thanks to the new ceiling panel design, it enables uniform air distribution, providing total comfort.  This system is ideal for small commercial applications.
 
An A-Class Cassette throughout

Key features

Light weight unit - for easy and quick installation

Simple maintenance, thanks to the self cleaning function and the Ag-ion top for anti-mould in drain cap.
 
Individual setting of louvre position: three different swing modes: standard, diagonally opposite, turn-around.

PDF Manuals available for this product


Product Specification

DIGITAL INVERTER

Indoor Unit (with DI)   RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E  
Cooling capacity (range) kW 5.0 (1.5 - 5.6) 7.1 (1.5 - 8.0) 10.0 (2.2 - 11.2)  
UK cooling capacity kW 5.44 7.46 10.87  
UK sensible capacity kW 4.26 5.25 6.67  
Heating capacity (range) kW 5.6 (1.5 - 6.3) 8.0 (2.2 - 9.0) 11.2 (2.2 - 12.5)  
UK heating capacity kW 4.69 6.72 9.68  
EER Cooling / COP Heating W/W 3.21 / 3.89 3.21 / 3.62 3.22 / 3.82  
Energy Efficiency Class (C/H)   A / A A / A A / A  
Indoor Dimensions mm 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840  
Grille RBC-U21PG(W) Dims mm 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950  
Airflow (low/medium/high) m3/h 726 / 835 / 1050 816 / 943 / 1200 1080 / 1320 / 1680  
Sound Pressure level (l/m/h) dB(A) 27 / 29 / 32 28 / 31 / 37 33 / 36 / 39  
Pipe gas - liquid In 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8  
Max. op current (cool) A 7.9 10.1 14.4  
Suggested fuse Size A 10 16 20  
Power Supply V-ph-Hz   240 - 1 - 50 240 - 1 - 50 240 - 1 - 50  
Supply taken to   Outdoor Unit Outdoor Unit Outdoor Unit  
Interconnecting Cables   3 + E 3 + E 3 + E  

 

Indoor Unit (with DI)   RAV-SM1404UT-E RAV-SM1604UT-E    
Cooling capacity (range) kW 12.5 (3.0 - 13.2) 14.0    
UK cooling capacity kW 12.61 15.53
UK sensible capacity kW 8.15 11.10
Heating capacity (range) kW 14.0 (3.0 - 16.0) 16.0
UK heating capacity kW 11.92 13.64
EER Cooling / COP Heating W/W 3.21 / 3.68 3.12 / 3.61
Energy Efficiency Class (C/H)   A / A B / A
Indoor Dimensions mm 319 x 840 x 840 319 x 840 x 840
Grille RBC-U21PG(W) Dims mm 30 x 950 x 950 30 x 950 x 950
Airflow (low/medium/high) m3/h 1200 / 1500 / 2040 1260 / 1500 / 2130
Sound Pressure level (l/m/h) dB(A) 34 / 38 / 47 36 / 40 / 45  
Pipe gas - liquid In 5/8 - 3/8 5/8 - 3/8
Max. op current (cool) A 17.7 21.48
Suggested fuse Size A 20 25
Power Supply V-ph-Hz   240 - 1 - 50 240 - 1 - 50
Supply taken to   Outdoor Unit Outdoor Unit
Interconnecting Cables   3 + E 3 + E

Click here to see outdoor unit for refrigerant circuit details

 
   

SUPER DIGITAL INVERTER

   
           
Indoor Unit (with SDI)   RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E
Cooling capacity (range) kW 5.0 (2.2 - 5.6) 7.1 (2.2 - 8.0) 10.0 (3.0 - 11.2) 12.5 (3.0 - 14.0)
UK cooling capacity kW 5.44 7.46 10.87 12.61
UK sensible capacity kW 4.26 5.25 6.67 8.15
Heating capacity (range) kW 5.6 (1.5 - 6.3) 8.0 (2.2 - 9.0) 11.2 (2.2 - 12.5) 14.0 (3.0 - 16.0)
UK heating capacity kW 4.69 6.72 9.68 11.92
EER Cooling / COP Heating W/W 3.21 / 3.89 3.21 / 3.62 3.22 / 3.82 3.21 / 3.68
Energy Efficiency Class (C/H)   A / A A / A A / A A / A
Indoor Dimensions mm 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 320 x 840 x 840
Grille RBC-U21PG(W) Dims mm 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950
Airflow (low/medium/high) m3/h 726 / 835 / 1050 816 / 943 / 1200 1080 / 1320 / 1680 1200 / 1500 / 2040
Sound Pressure level (l/m/h) dB(A) 27 / 29 / 32 28 / 31 / 37 33 / 36 / 39 34 / 38 / 47
Pipe gas - liquid In 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8
Max. op current (cool) A 7.17 8.95 11.24 16.21
Suggested fuse Size A 10 10 20 20
Power Supply V-ph-Hz   240 - 1 - 50 240 - 1 - 50 240 - 1 - 50 240 - 1 - 50
Supply taken to   Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit
Interconnecting Cables   3 + E 3 + E 3 + E 3 + E

Click here to see outdoor unit for refrigerant circuit details