TOSHIBA > RESIDENTIAL > DC-INVERTER MULTI-SPLIT OUTDOOR

 

- Smallest 5 hp unit in the market
- Light weight
- Up to 70 m of pipe run

 

 

R410A
DC HYBRID INVERTER
MULTI-SPLIT OUTDOOR UNITS

Outdoor
Multi-split residential.


Features

Toshiba multi-splits are equipped with the Toshiba DC hybrid inverter, an enhanced air conditioning system that ensures greater performance and reliability. Thanks to the efficient DC compressors, this unit provides fast and precise temperature management, along with superior energy savings, 40-50% compared to fixed-speed systems.
Key features

Wider range of indoor units available: high-wall, ducted and the innovative Daiseikai, for 2-room multi-split applications.

A perfect combination of DC twinrotary compressor, DC hybrid inverter and R410A refrigerant.

Superior reliability, due to the reduction of the compressor ON/OFF cycles.

Compact and light: The smallest 5 hp outdoor unit in the industry at 795 x 900 x 320 mm.

Extremely quiet: the unit operates at only 48 dB(A).

Flexibility is assured with this system that enables up to 25 m piping length for one room ensuring the overall length is not exceeded. An example of a fourroom application where the overall length is 70 m - Room 1: 25 m, Room 2: 20 m, Rooms 2 and 4: 10 m each.


PDF Manuals available for this product

 


Product Specification
 

Outdoor Unit - Heat Pump   RAS-M14GAV RAS-M18GAV RAS-3M23GAV  
No Rooms   2 2 3  
Cooling Capacity kW 1.1 - 4.5 1.1 - 6.2 1.4 - 7.0  
Heating Capacity kW 0.5 - 5.2 0.7 - 8.5 0.8 - 10.8  
EER Cooling / COP Heating W/W 3.25 / 3.62 3.70 / 4.35 3.33 / 3.53  
Energy Efficiency Class   A / A A / A A / B  
Outdoor Dimensions mm 550 x 780 x 290 550 x 780 x 290 795 - 900 - 320  
Pipe gas - liquid In 3/8x2 - 1/4x2 3/8x2 - 1/4x2 1/2 + 3/8x2 - 1/4x3  
Pipe Length Max Unit / Total m 20 / 30 20 / 30 20 / 40  
Pipe Length Max Height Diff m 10 10 10  
Refrigerant Pre-charge m 30 30 40  
Additional R410A charge g/m n/a n/a n/a  
Max. op current (cool) A 6.9 7.2 10.8  
Suggested fuse Size A 10 10 16  
Power Supply V-ph-Hz   240 - 1 - 50 240 - 1 - 50 240 - 1 - 50  
Supply taken to   Outdoor Unit Outdoor Unit Outdoor Unit  
Interconnecting Cables   3 + E 3 + E 3 + E  
           
Outdoor Unit - Heat Pump   RAS-4M27GAV RAS-5M34UAV    
No Rooms   4 5    
Cooling Capacity kW 1.4 - 9.2      
Heating Capacity kW 0.8 - 11.0      
EER Cooling / COP Heating W/W 3.2 / 4.0 3.42/4.24    
Energy Efficiency Class   B / A      
Outdoor Dimensions mm 795 - 900 - 320 890 - 900 - 320    
Pipe gas - liquid In 1/2 + 3/8x3 - 1/4x4      
Pipe Length Max Unit / Total m 25 / 70 25 / 80    
Pipe Length Max Height Diff m 15 15    
Refrigerant Pre-charge m 70 40    
Additional R410A charge g/m n/a      
Max. op current (cool) A 10.6      
Suggested fuse Size A 16      
Power Supply V-ph-Hz   240 - 1 - 50 240 - 1 - 50    
Supply taken to   Outdoor Unit Outdoor Unit    
Interconnecting Cables   3 + E 3 + E